How to Read an Audiogram: Your Hearing Test Results Explained

Originally published: November 5, 2026
Last updated: October 28, 2026

How do you read an audiogram?

An audiogram is a chart of the quietest sounds you can hear at different pitches. Pitch runs from low on the left to high on the right, and loudness runs from quiet at the top to loud at the bottom, so the lower your results sit on the chart, the louder a sound had to be before you could hear it. For adults, results down to about 20 dB HL are generally considered within the normal range. The shape of the results, and how your two ears compare, matter as much as any single number.

This guide explains the two axes, the symbols you are likely to see, how hearing loss is usually described, what the shape of an audiogram can suggest, and what an audiogram cannot tell you on its own.

The two axes: pitch and loudness

Frequency (pitch)

The horizontal axis shows frequency, measured in hertz (Hz). A standard hearing test usually checks pitches from around 250 Hz, a low hum, up to 8,000 Hz, a high whistle. Speech is spread across this range: vowel sounds are mostly lower in pitch, while many consonants, such as “s”, “f” and “th”, are higher. That is why a loss in the higher pitches can make speech sound unclear rather than simply quiet.

Hearing level (dB HL)

The vertical axis shows hearing level in decibels (dB HL). Zero dB HL represents the quietest sound that young adults with healthy ears can typically hear at each pitch. It is a relative scale, so the numbers on an audiogram are not the same as the decibel levels used to describe everyday noise.

What the symbols mean

Each mark on the chart is a threshold: the quietest level at which you responded to a sound at that pitch. Conventions vary a little between services, but these are common.

SymbolWhat it usually shows
Circle (often red)Right ear, tested through headphones or earphones (air conduction)
Cross (often blue)Left ear, tested through headphones or earphones (air conduction)
Brackets or arrowheadsBone conduction, tested with a small vibrator placed behind the ear, which bypasses the outer and middle ear
Downward arrowNo response at the loudest level tested

Your audiologist should always explain your own chart, including any symbols specific to how your test was carried out.

How hearing loss is described

In the UK, audiologists commonly use the British Society of Audiology’s descriptors, based on the average hearing level across key frequencies.

Hearing levelUsual descriptionWhat it may mean day to day
Up to 20 dB HLWithin the normal rangeMost everyday sounds are heard comfortably
21 to 40 dB HLMildQuiet speech and soft sounds may be missed, especially in background noise
41 to 70 dB HLModerateFollowing conversation is often difficult without support
71 to 95 dB HLSevereMuch of normal speech is not heard without amplification
Over 95 dB HLProfoundVery loud sounds may be heard, but speech is usually not

These descriptions are a useful guide, but they do not tell the whole story. Two people with similar audiograms can experience their hearing very differently.

Older man wearing headphones during a Pure Tone Audiometry hearing test to assess hearing thresholds across different frequencies

What the shape of an audiogram can suggest

  • Sloping down to the right: hearing is better for low pitches than high pitches. This pattern is common, including with age-related hearing loss, and often makes speech sound mumbled, particularly in noise.
  • A dip around 3,000 to 6,000 Hz: sometimes called a “noise notch”, this pattern is often associated with exposure to loud noise.
  • Fairly flat: hearing is reduced by a similar amount across the pitches tested.
  • One ear quite different from the other: an uneven result can have several causes and may need further investigation, so your audiologist may suggest you see your GP.

Air and bone conduction: types of hearing loss

Comparing the air conduction and bone conduction results helps to show where a hearing problem may be coming from.

  • Conductive hearing loss: bone conduction results are better than air conduction results. This suggests that sound is not travelling through the outer or middle ear as well as it should, for example because of ear wax or fluid.
  • Sensorineural hearing loss: air and bone conduction results are reduced by a similar amount. This points to the inner ear or the hearing nerve.
  • Mixed hearing loss: a combination of the two.

What an audiogram does not show

A standard audiogram measures how quiet a sound can be before you hear it. It does not show how well you understand speech, how much effort listening takes, or how you cope in a busy restaurant or meeting. Many people with a “mild” audiogram find conversations in noise genuinely difficult.

That is why a fuller assessment looks beyond the chart, including how well you follow speech in background noise. It is also why an audiogram on its own does not decide whether hearing aids are right for you.

When to seek medical advice

If you notice sudden hearing loss in one or both ears, ask for an urgent GP appointment or contact NHS 111. See your GP if hearing loss is getting worse, affects one ear more than the other, or comes with ear pain, discharge or dizziness.

Sources

Frequently asked questions

Is 20 dB hearing loss normal?

For adults, hearing levels down to about 20 dB HL are generally considered within the normal range. Results just below this line are usually described as a mild hearing loss, but how much it affects you depends on the pitches involved and your listening situations.

Why can I hear people but not understand them?

Many consonant sounds are high in pitch and quieter than vowels. If your hearing is reduced in the higher pitches, speech can be loud enough to hear but not clear enough to follow, especially when there is background noise.

Does an audiogram show whether I need hearing aids?

Not on its own. The decision also depends on how well you understand speech, the situations you find difficult and what you want to achieve. An audiologist brings these together when discussing your options.

Can I have a copy of my results?

You can ask your hearing care provider for a copy of your audiogram. At Hearing Healthcare Centre, a Hear-IQ assessment includes a written report.

Understand your hearing in detail

A Hear-IQ hearing assessment goes further than a standard audiogram. It looks at your hearing, how well you understand speech, including in background noise, and the listening situations that matter to you, and your audiologist explains the results with you. It costs £120 at either clinic, you should allow up to two hours, and you receive a written report. There is no obligation to buy and no pressure to decide on the day.

We are an independent, family-run practice with HCPC-registered audiologists and an AIHHP Centre of Excellence, with clinics in Cambridge and Saffron Walden.

Book Your Hear-IQ Hearing Assessment

Not sure which appointment you need? Read how long a hearing test takes and what each assessment involves, or find out more about Hear-IQ.

Related articles

Behind Every Small Business Is a Family, Not a Billionaire

Help & Advice

Behind Every Small Business Is a Family, Not a Billionaire

Most UK businesses are small, and behind ours is a family. The story of Hearing Healthcare Centre and what being independent means for your hearing care.

November 15, 2026

Are Earbuds Bad for Your Ears?

Help & Advice

Are Earbuds Bad for Your Ears?

Are earbuds bad for your ears? Earbuds are not harmful in themselves. The main risk to your hearing comes from listening too loudly for too long, which can permanently damage the delicate structures of the inner ear. The World Health Organization advises keeping the volume below 60% of your device’s maximum, limiting how long you […]

November 12, 2026

Are Women More Attuned to the Cry of a Baby?

Help & Advice

Are Women More Attuned to the Cry of a Baby?

Are women more attuned to a baby crying? What brain research shows, why fathers recognise their baby’s cry as well, and what to do if you struggle to hear.

November 9, 2026